Tion Is an expert in cleanliness, sterility and air safety. Professional equipment manufactured by our company is used for high-performance cleaning and decontamination of air in a variety of areas: from medical facilities to clean production of different classes of cleanliness.
Modern professional equipment for cleaning and decontamination of air Tion simultaneously filters and decontaminates from harmful substances and odors. It ensures that the smell is cleaned and the air in the premises is fully compliant with the requirements of the existing standards, regulations and legislation.
Organisation of air exchange in residential buildings with natural ventilation Natural ventilation of buildings must comply with hygienic standards for air exchange. Air exchange must be provided with a multiplicity of at least 3 m3/ h perOne m2 of living space or 30 m3/ h per person (for multi-apartment buildings“Multi-apartment residential buildings”; for single-family houses and cottages: “Residential single-family houses”). Until recently, the natural flow of air was regulated through window sashes, transoms and windows was regulated. Modern sealed window packages provide an air flow of not more than 6-7 m3/ h, and slotted window valves give no more than 15 m3/ h to the entire room. Therefore, to comply with the norms of air exchange we recommend the installation in each room of devices that provide forced airflow.Equipment: compact supply ventilation Breezer Tion O2 or our flagship model Breezer TION 3S with air purification (up to 120 m3 / h, HEPA class air purification, climate control)
2 Mechanical ventilation of houses: air exchange and air purification Forced central ventilation of buildings in the maintenance mode should have a capacity of at least a single exchange of air volume for an hour in rooms with a constant stay of people. At least 60 m3/ h should be removed from the kitchen in maintenance mode, and 25 m3 / h from the bathtub and toilet.If there are air conditioning systems, it is also advisable to clean and disinfect the air in the ventilation. The design of ventilation with the installation of an air purifier in the supply duct makes it possible to ensure hygienic standards of air purity in all rooms, to eliminate the risk of the occurrence and spread of Legionella bacteria (a problem arises when the air conditioning systems are not regularly serviced), and also reduce the operational costs of ventilation maintenance, by several times reducing the frequency of scheduled cleaning ventilation ducts from pollution.Equipment: In the supply air duct: channel disinfectant Tion Eco air purifier (from 300 to 25000 m3/ h)
3 Cleaning and disinfecting indoor air If there is no central ventilation with air purification in rooms where there are strong sources of air pollutants (for example, if there are smokers for sick people in the room), it is advisable to install self-contained disinfecting air purifiers.Equipment: Tion Clever bactericidal air purifier (up to 150 m3/ h, H11 filtration, 99.9% disinfection, air purification from harmful substances to MPC standards)
Ventilation of mini-hotels, hotels with natural ventilation Building standards in hotels and mini-hotels of small capacity. The air exchange rate is regulated by the number of stars: for category 5 ***** - 70 m3/ h; 4 **** - 60 m3 / h; 3*** - 40 m3/ h; 2 **; 1 * - 30 m3 / h.For natural ventilation, it should be borne in mind that sealed window packages provide an air flow of no more than 6-7m3/ h, which necessitates the additional equipment of rooms with ventilation devices with forced and controlled air flow. “Public buildings and structures” : “For rooms not equipped with a mechanical ventilation system,devices should be provided for supplying outdoor air at a height of at least 2 m from the floor” .In rooms with smoking, the minimum air exchange rate is 100 m3/ h (since 2014 smoking in rooms is prohibited No. 15 FZ and is allowed only in specially equipped rooms on the floor). Installation of air disinfecting cleaners working in the 100% air recirculation mode will help to increase the rate of air exchange and effectively clean the air of dust, tobacco smoke and other harmful substances.Equipment: compact supply ventilation Breezer Tion O2 or our flagship model Breezer TION 3S with air purification (up to 120-160 m3/ h, HEPA class air purification, climate control; individual installation in each room).In rooms with smoking: a professional Tion Clever air purifier up to 150 m3 / h, H11 filtration, 99.9% disinfection, purification of air from tobacco smoke and harmful substances to MPC standards)
2Reduced energy costs due to air recirculation in hotel mechanical ventilation systems In all hotels, with the exception of hotels with low capacity, in the absence of air conditioning systems in the building as a whole or in its separate parts, it is necessary to provide for supply and exhaust ventilation with mechanical induction of exhaust in all the main rooms; with mechanical provision of the inflow - in the lobby, halls,hall complex, pool hall, dining halls of catering establishments with more than 50 seats. Due to the significant volumes of air processed by ventilation (especially in the presence of hall rooms), it is allowed to apply air recirculation provided that it is cleaned and disinfected. For this, a recirculation branch with a duct installation of integrated air purification is added to the supply ventilation. Part of the air is supplied by the supply system, and part is taken by an exhaust fan from the room,undergoes multi-stage cleaning and disinfection in a channel cleaner and is again fed into the room. Thus, not all air, but only part of it is taken from the street, which can significantly reduce the energy consumption of ventilation for its processing. This method of organising ventilation makes it possible to simultaneously increase the energy efficiency of the facility, reduce operating costs for cleaning ventilation ducts, eliminate the risk of developing legionellosis in the building, to clean the supply air from dust in mechanical ventilation and air conditioning systems to the MPC. which can significantly reduce the energy consumption of ventilation for its processing. This method of organising ventilation makes it possible to simultaneously increase the energy efficiency of the facility, reduce operating costs for cleaning ventilation ducts, eliminate the risk of developing legionellosis in the building and, according to clause ,clean the supply air from dust in mechanical ventilation and air conditioning systems to the MPC. which can significantly reduce the energy consumption of ventilation for its processing. This method of organising ventilation makes it possible to simultaneously increase the energy efficiency of the facility, reduce operating costs for cleaning ventilation ducts, eliminate the risk of developing legionellosis in the building and, clean the supply air from dust in mechanical ventilation and air conditioning systems to the MPC.Equipment: channel cleaners Tion Eco air disinfectors (productivity from 400 to 27500 m3 / h)
Organisation of air exchange in office rooms with natural ventilation For rooms of offices, offices of public buildings for administrative purposes, air exchange must be provided according to Standard Practises at least 40 m3 / h for 1 person with natural ventilation in the room and at least 60 m3/ h for mechanical ventilation. In this case, until recently, the natural flow of air was regulated through adjustable window sashes, transoms and windows. Since modern sealed window packages provide an air flow of not more than 6-7 m3/ h, and slotted window valves give no more than 15 m3/ h to the entire room, it is recommended that air supply devices are installed in each room that ensure forced, adjustable and adequate airflow Equipment: compact supply ventilation Breezer Tion O2 or our flagship model Breezer TION 3S with air purification (up to 120-160 m3/ h, HEPA class air purification, climate control)Mechanical Ventilation of houses: air exchange and air purification
2Smoking area In accordance with No Smoking Laws “On the protection of the health of citizens from the effects of ambient tobacco smoke and the consequences of tobacco consumption”, smoking is prohibited in office rooms, but is allowed in specially isolated rooms that are equipped with ventilation systems. The ventilation of smoking rooms can be organised with the help of a productive supply and exhaust system, providing a high rate of air exchange in the room. However, this method requires high energy consumption of the ventilation system. Another option is the organisation of recycling within the same room. For this, a recirculation branch with a duct installation of integrated air purification is added to the supply ventilation. Part of the air is supplied by the supply system, and part is taken by the exhaust fan from the room, passes a multi-stage purification from tobacco smoke in a channel cleaner and is again fed into the room. This allows you to provide a high rate of air exchanged within a single room and significantly reduce ventilation energy consumption when organising a smoking area.Equipment: channel disinfectant Tion Eco purifier (from 300 to 25000 m3 / h) for the supply ventilation channel.
3 Reduction of energy consumption due to recirculation and air purification in ventilation and air conditioning system In office buildings, in order to reduce the amount of outdoor air supplied by the ventilation system, it is allowed to use a ventilation system with partial air recirculation (part of the air is taken in by the ventilation system from the street, and part is mixed from the room), provided it is cleaned and disinfected on filters,This Allows you to significantly save energy on heating or cooling the supply air by the ventilation system.If there are air conditioning systems in office buildings and business centres, ventilation with air purification and its disinfection is also advisable. Installing an air purifier in the ventilation supply duct makes it possible to ensure hygienic standards for air purity in all rooms, to eliminate the risk of the occurrence and spread of Legionella Bacteria (a problem arises when the air conditioning systems are not regularly serviced), and also reduce the operational costs of discussing ventilation, by several times reducing the frequency of scheduled cleaning of ventilation ducts from pollution.Equipment: channel disinfectant Tion Eco purifier (from 300 to 25000 m3 / h) for the supply ventilation channel
4 Cleaning and disinfecting indoor air If there is no central ventilation with air purification in rooms where there are strong sources of air pollutants (for example, if there are smokers or sick people in the room), it is advisable to install self-contained disinfecting air purifiers.Equipment: Tion Clever bactericidal air purifier (up to 150 m3 / h, H11 filtration, 99.9% disinfection, air purification from harmful substances to MPC standards)
Organisation of air exchange in institutions In the premises of the preschool educational institution of reception, bedrooms, dressing rooms, nurseries, junior, middle, senior, preschool groups, as well as medical units and halls for music and gymnastics, the ventilation rate must be at least 2.5 times per hour. Since a child needs at least 20 m3/ for breathing, with an average number of children and staff in a group of 20 people, the minimum air exchange rate is 400 m3/ h, taking into account the requirements for a multiplicity of 2.5, at least 1000 m3 m3 h per room. Due to natural ventilation through slots in transoms and vents (inflow no more than 5-10 m3 h through 1 window) it is impossible to ensure even a minimum inflow rate. Hourly full ventilation of the room with open windows,especially in the cold season, is dangerous for the health of children. Thus, it is necessary to equip the room with a full central ventilation system, or install additional supply devices of sufficient capacity Equipment: fresh air disinfect-or (compact ventilation)Breezer Tion O2 or our flagship model Breezer TION 3S with air purification (up to 120-160 m3/ h, HEPA class air purification, climate control)
2 Indoor air disinfection and cleaning In the medical office of educational institutions (schools, colleges, etc.),disinfection should be provided. It is also recommended to install bactericidal air disinfection and purification plants. In addition, air disinfection is also advisable in rooms where children are constantly staying, especially during periods of growing number of diseases with airborne infections to reduce the incidence in pre-school groups. The placement of purifiers disinfectants allows the complex to improve sanitary and hygienic indicators in terms of air purity and air exchange rate.Equipment: Tion Clever (up to 150 m3/ h, H11 filtration, 99.9% disinfection, air purification from harmful substances to MPC standards,registration certificate for medical equipment)
3 Ventilation air purification In large and industrial cities, the concentrations of harmful substances in the places of placement of children's institutions often exceed the maximum permissible concentrations (MPC), while the concentration of harmful air substances in rooms with a constant stay of children (group, games,bedrooms, halls for music and physical education classes and others) should not exceed the maximum permissible concentrations (MPC) for the atmospheric air of populated areas. To solve this problem, at the design stage, integrated air purification installations should be laid in the ventilation supply duct. This will protect children and staff of the preschool educational institution from adverse environmental conditions and comply with sanitary standards.Equipment: channel cleaners Tion Eco air disinfect-ors (productivity from 400 to 27500 m3/ h)
Natural ventilation of sports halls: organisation of air exchange Sports halls without seats for spectators and fitness clubs with a volume of at least 80 m3 for each one engaged at a time can be designed with natural supply and exhaust ventilation with a one-time air exchange per hour .The standards are proposed to achieve this air exchange by ventilating the room with window transoms and windows. Obviously, the hourly full ventilation of the room with windows, accompanied by drafts,especially in the cold season, does not contribute to improving health. If we consider that in the closed state modern window structures allow air to pass no more than 5-10 m3/ h through 1 window, then it is clear that this method cannot fulfil the norm of 80 m3 / h for 1 person.Decision. If there is no possibility or means to equip the room with a central ventilation system, the problem can be solved by installing compact air supply devices that provide additional air flow with the windows closed.Equipment: compact supply ventilation Breezer Tion O2 or our flagship model Breezer TION 3S with air purification (up to 120-160 m3/ h, HEPA class air purification, climate control)
2 Gym ventilation: increased air exchange rate For small gyms, it is possible to increase the air exchange rate to the required one, in addition to installing additional air supply devices, by installing stand-alone disinfectant cleaners operating in the 100% air recirculation mode. The multiplicity is regulated by the number and performance of disinfecting cleaners, as well as depending on the volume of the premises served. The installation of disinfecting cleaners will also help get rid of the characteristic smell in gyms and reduce microbial airborne contamination.Equipment: Tion Clever bactericidal air purifier (up to 150 m3/ h, H11 filtration, 99.9% disinfection, air purification from harmful substances to MPC standards)
3 Reduced energy consumption due to recirculation in the ventilation system For sports halls (including those with seats for spectators) equipped with a central system of supply and exhaust ventilation, significant energy consumption of ventilation is characteristic for maintaining the required air exchange and temperature and humidity parameters of the air. To Reduce the cost of electricity at such facilities, it is allowed to use recirculation with air purification: part of the air is supplied from the street,and part is taken from the room, passes through the air filtration and disinfection device, and is again supplied to the room. This allows you to ensure compliance with sanitary standards and at times reduce the cost of maintenance of ventilation of sports facilities.Equipment: channel cleaners Tion Eco air disinfectors (productivity from 400 to 27500 m3/ h)
Reduced energy consumption due to recirculation in the ventilation system The ventilation system of supermarkets and shopping centres is usually carried out with air conditioning, which requires very significant energy costs. To reduce them,“Retailers”, “Public buildings and structures”they allow in the trading floors of stores, in addition to the trading floors with chemical, synthetic or odorous substances and flammable liquids, to use air recirculation with its cleaning and disinfection. Part of the air(calculated, but not less than 20 m3 / h per person) is taken by the ventilation system from the street, and the rest is taken from the serviced premises, then all the air passes through the channel air purification and disinfection unit, which is built into the ventilation supply duct, and enters the room again. This allows you to significantly reduce energy costs for cooling and heating the supply air and to ensure compliance with sanitary standards for air quality.Equipment: channel cleaners Tion Eco air disinfect-ors (productivity from 400 to 27500 m3 / h)
2Ventilation design for shopping centres with exhaust air cleaning for kitchens In the kitchens of food courts, restaurants on the territory of shopping centres and in the hot shops of supermarkets, an exhaust ventilation system is organised to remove smoke, combustion products and kitchen odors from the premises. At the same time, it is not always possible to remove the exhaust duct above the roof ridge, which is required by sanitary standards. To solve this problem, an integrated air purification units built into the exhaust ventilation system immediately after the spark arrester and grease trap, which effectively purifies the air from the exhaust products of furnaces, barbecues, and grills of hot shops. This allows you to throw out air at the ground floor level, without causing inconvenience to people living or working in the neighbourhood.Equipment: For purification of exhaust air of all types of stoves (except wood and barbecue): Duct air purifiers Tion Ext (capacity from 400 to 27500 m3 / h); for purification of exhaust air from wood stoves and barbecues: duct air purifiers Tion Ext Advanced capacity from 2000 to 6000 m3 / h)
Exhaust air purification of the hot shop For public catering, the problem of food and smoke odors that are emitted into the living area is often relevant. It is often too expensive to remove the duct above the roof ridge or it is not possible to coordinate the duct on the facade. Complaints of tenants can make it impossible for the institution to work, and also make it difficult to obtain a positive assessment of project documentation. The only solution is to eliminate the very essence of the problem - to clean the exhaust air from smoke and odor. For this, the ventilation of the restaurant is equipped with a comprehensive air purification system. It is located immediately after the spark arrester and grease trap and effectively cleans the air of hotshops, barbecues, grills and other sources of smoke and smell. This makes it possible to equate the exhaust air of the kitchen to household emissions and discharge air at the level of the first floor.Equipment: For purification of exhaust air of all types of stoves (except wood and barbecue): Duct air purifiers Tion Ext (capacity from 400 to 27500 m3 / h); for purification of exhaust air from wood stoves and barbecues: duct air purifiers Tion Ext Advanced (capacity from 2000 to 6000 m3 / h)
2Cleaning and disinfection of the supply air of confectionery shops and other premises for cooking food In the confectionery decoration rooms, the supply ventilation system must be carried out with a dust and bactericidal (disinfecting) filter, which provides fresh air in this room. At the same time, it is recommended to provide for purification of the supplied outside air in mechanical forced ventilation systems. “The content of harmful substances in the air of industrial premises of the shops of public catering enterprises should not exceed the maximum permissible concentration (MPC) of harmful substances in the air of the working area. Such harmful substances include dust, flour, sugar and other fine particles that fall from the production area into the air of the workshop and can settle on the lungs of plantpersonnel.Equipment: For comprehensive cleaning and disinfection of air: channel cleaners air disinfectants Tion Eco (capacity from 400 to 27500 m3 / h)
Protecting critical food operations To protect critical operations, such as aseptic food production and bottling, including in the dairy and meat processing industry, it is necessary to organise local clean zones off ISO 5 class. For this, it is necessary to use air-cleaning equipment (for example, laminar cells that are built into a suspended ceiling ), providing unidirectional vertical air flow with filtration not lower than class H14 and disinfection and inactivation of microorganisms to the MPC level of microbial contamination ulcer of clean zones.This will prevent contamination (pollution) of products from the air and ensure the safety and quality of the finished product.Equipment: TION Laminar ceilings and cells Tion V Lam M2.
2 Cleaning and disinfecting air in ventilation to protect containers, raw materials, production and storage of products In the mechanical ventilation systems of the discussing and auxiliary zones of clean food production in which transportation, filling of containers and other stages are carried out, it is necessary to provide for disinfection, as well as cleaning of the supply air from harmful substances and dust,Heating,ventilation and air conditioning ”.“ Production of milk and dairy products ”. Filtering of class H11-H13 is recommended (class ISO6 - for surrounding areas, ISO 7, ISO 8 - for auxiliary). For this, integrated cleaning plants are built into the supply ventilation system, air passes through a filtration and disinfection system and enters the room through ceiling air diffusers. This ensures protection against infection from the air during packaging operations,Equipment: for the supply channel: channel cleaners Tion Eco air disinfect-ors (capacity from 400 to 27500 m3 / h); for the purification of polluted exhaust exhaust channel: channel air purifiers Tion Ext (Page-38) capacity from 400 to 27500 m3 / h)
3 Diminution in rooms with out natural ventilation To protect against bio-pollution from air in small rooms, including where a ventilation system is not provided (laboratory rooms, etc.) with air purification, it is advisable to use bactericidal re-circulators (disinfecting air purifiers). Re-circulators are effective in the workshops for the preparation of containers and raw materials; in warehouses of raw materials and finished products, including to prevent premature ripening of fruits andvegetables.Equipment: bactericidal air purifier) Tion Clever up to 150 m3/ h, H11 filtration, 99.9% disinfection, air purification from harmful substances to MPC standards); for additional ventilation of the room: compact supply ventilation Breezer Tion O2 or our flagship model Breezer TION 3S with air purification (up to 120-160 m3/ h, HEPA class air treatment, climate control).
Protecting critical areas of operations To protect critical operations, such as operation rooms, medical and chemical Labs, it is necessary to organise local clean zones off ISO 5 class. For This, it is necessary to use air-cleaning equipment (for example, laminar cells that are built into a suspended ceiling ), providing unidirectional vertical air flow with filtration not lower than class H14 and disinfection and inactivation of microorganisms to the MPC level of microbial contamination ulcer of clean zones.This will prevent contamination (pollution) of products from the air and ensure the safety and quality of the finished product.Equipment: TION Laminar ceilings and cells Tion V Lam M2.
2 Cleaning and disinfecting air in ventilation to protect patients and medical personnel In the mechanical ventilation systems of the discussing and auxiliary zones of clean operation rooms, medical and chemical labs where chances of contamination is possible ,it is necessary to provide for disinfection, as well as cleaning of the supply air from harmful substances and dust,Heating,ventilation and air conditioning ”. Filtering of class H11-H13 is recommended (class ISO6 - for surrounding areas, ISO7, ISO 8 - for auxiliary). For this,integrated cleaning plants are built into the supply ventilation system, air passes through a filtration and disinfection system and enters the room through ceiling air diffusers. This ensures protection against infection from the air during operations,Equipment: for the supply channel: channel cleaners Tion Eco air disinfect-ors (capacity from 400 to 27500 m3/ h); for the purification of polluted exhaust exhaust channel: channel air purifiers Tion Ext (Page-32) (capacity from 400 to 27500 m3 / h)
3 Diminution in rooms with out natural ventilation To protect against bio-pollution from air in small rooms, including where a ventilation system is not provided (laboratory rooms, etc.) with air purification, it is advisable to use bactericidal re-circulators (disinfecting air purifiers). Re-circulators are effective in operation rooms, medical and chemical Lab Equipment: bactericidal air purifier) Tion Clever up to 150 m3 / h, H11 filtration, 99.9% disinfection, air purification from harmful substances to MPC standards); for additional ventilation of the room: compact supply ventilation Breezer Tion O2 or our flagship model Breezer TION 3S with air purification (up to 120-160 m3/ h, HEPA class air treatment, climate control).
Protecting critical areas of operations To protect critical operations, such as operation rooms. it is necessary to organise local clean zones off ISO 5 class. For This, it is necessary to use air-cleaning equipment (for example, Tion EXT / Advanced can be installed behind a false ceiling indoors, in a separate ventilation chamber or outdoors), providing unidirectional vertical air flow with filtration not lower than class H14 and disinfection and inactivation of microorganisms to the MPC level of microbial contamination ulcer of clean zones.This will prevent contamination (pollution) of products from the air and ensure the safety people working in the facilities as well as the environment.
2 Cleaning and disinfecting air in ventilation to protect the environment.The filter made of polypropylene fibers captures particles, aerosols and microorganisms with filtration efficiency class E11 (H11) - H14. Tion EXT / Advanced The highly efficient chemical absorber Tion deeply cleans the air from gases, harmful substances and odors through a special mixture of sorbents and catalysts (absorbs and deactivates harmful substances O 3 , H 2 S, NH 3 , RSH).In the mechanical ventilation systems of the discussing and auxiliary zones,it is necessary to provide for disinfection, as well as cleaning of the supply air from harmful substances and dust.