•Healthimpact
•According To WHO, indoor air pollution is the major risk factor for human health
•Guidelines Of WHO on indoor air quality :
1.European Standards EN 13779 and EN 15251
2.GOST30494-2013 Residential, Hotels and public buildings. Indoor microclimate parameters
3.GOST56502-2015 Microclimate systems for new buildings
•PM2.5/ PM10 particles increase the risk of strokes, respiratory diseases, lung cancer
•Some Molecular contaminants typical for indoor areas increase the risk of allergic reactions and cancer
•https://www.epa.gov/indoor-air-quality-iaq/introduction-indoor-air-quality
•The risk of infection is significantly higher in cool and dry rooms•Productivity Impact, employees can be 60% more productive at work with comfortable air conditioner
•The Quality of concentration required tasks increases as CO₂ levels decreases
•Optimal Temperature and humidity parameters drop down sick-leave costs
1.To Create safe clean air ,comfortable ,infection free environment for guests and working staff employees
2.Significantly Reducing transmission of infections to cut down on loss in company revenues resulted from sick day leaves or guests getting sick from staying or working at the hotel.
3.To Boost focus and performance of employees by cutting down on CO2 build ups.
To solve the voiced problem, it is necessary to equip the hotel rooms and premises with Tion equipment that can provide the needed results.
Ventilation of mini-hotels, hotels with natural ventilation Building standards in hotels and mini-hotels of small capacity. The air exchange rate is regulated by the number of stars: for category 5 ***** - 70 m3/ h; 4 **** - 60 m3 / h; 3*** - 40 m3/ h; 2 **; 1 * - 30 m3 / h.For natural ventilation, it should be borne in mind that sealed window packages provide an air flow of no more than 6-7m3/ h, which necessitates the additional equipment of rooms with ventilation devices with forced and controlled air flow. “Public buildings and structures” : “For rooms not equipped with a mechanical ventilation system,devices should be provided for supplying outdoor air at a height of at least 2 m from the floor” .In rooms with smoking, the minimum air exchange rate is 100 m3/ h (since 2014 smoking in rooms is prohibited No. 15 FZ and is allowed only in specially equipped rooms on the floor). Installation of air disinfecting cleaners working in the 100% air recirculation mode will help to increase the rate of air exchange and effectively clean the air of dust, tobacco smoke and other harmful substances.Equipment: compact supply ventilation Breezer Tion O2 or our flagship model Breezer TION 3S with air purification (up to 120-160 m3/ h, HEPA class air purification, climate control; individual installation in each room).In rooms with smoking: a professional Tion Clever air purifier up to 150 m3 / h, H11 filtration, 99.9% disinfection, purification of air from tobacco smoke and harmful substances to MPC standards)
2Reduced energy costs due to air recirculation in hotel mechanical ventilation systems In all hotels, with the exception of hotels with low capacity, in the absence of air conditioning systems in the building as a whole or in its separate parts, it is necessary to provide for supply and exhaust ventilation with mechanical induction of exhaust in all the main rooms; with mechanical provision of the inflow - in the lobby, halls,hall complex, pool hall, dining halls of catering establishments with more than 50 seats. Due to the significant volumes of air processed by ventilation (especially in the presence of hall rooms), it is allowed to apply air recirculation provided that it is cleaned and disinfected. For this, a recirculation branch with a duct installation of integrated air purification is added to the supply ventilation. Part of the air is supplied by the supply system, and part is taken by an exhaust fan from the room,undergoes multi-stage cleaning and disinfection in a channel cleaner and is again fed into the room. Thus, not all air, but only part of it is taken from the street, which can significantly reduce the energy consumption of ventilation for its processing. This method of organising ventilation makes it possible to simultaneously increase the energy efficiency of the facility, reduce operating costs for cleaning ventilation ducts, eliminate the risk of developing legionellosis in the building, to clean the supply air from dust in mechanical ventilation and air conditioning systems to the MPC. which can significantly reduce the energy consumption of ventilation for its processing. This method of organising ventilation makes it possible to simultaneously increase the energy efficiency of the facility, reduce operating costs for cleaning ventilation ducts, eliminate the risk of developing legionellosis in the building and, according to clause ,clean the supply air from dust in mechanical ventilation and air conditioning systems to the MPC. which can significantly reduce the energy consumption of ventilation for its processing. This method of organising ventilation makes it possible to simultaneously increase the energy efficiency of the facility, reduce operating costs for cleaning ventilation ducts, eliminate the risk of developing legionellosis in the building and, clean the supply air from dust in mechanical ventilation and air conditioning systems to the MPC.Equipment: channel cleaners Tion Eco air disinfectors (productivity from 400 to 27500 m3 / h)
Tion allows for solution of all problems related to contaminated air removal both inside and outside the building.