Tion is a comprehensive purification and decontamination technology that not only allows air to be filtered with the highest efficiency and provides complete inactivation (destruction) of all microorganisms-viruses, but also removes the main harmful substances in gas form. The Tion technology is based on the combined work of filters, which effectively removes all impurities from the air. This enables all air purification and decontamination problems to be solved, including those that could not be managed using traditional methods, such as fabric or paper HEPA filters, UV bactericidal sections, sorption, electrostatic filters or combinations of these. The Tion equipment as a whole complies with healthcare regulations requirements.
Protection of Critical Operations in Drug Manufacturing:Unidirectional airflow devices are used to protect critical operations such as filling and capping against airborne contamination. The laminar ceiling or cell is built into the ventilation supply duct directly into the ceiling above the working area and provides a continuous supply of purified and sterile unidirectional air flow. The device must provide air filtration of class H14 and inactivation of microorganisms on filters at least 99% (requirements for class A according to SanPiN 2.1.3.2630-10). The area of the laminar field of the device is selected depending on the area of the working area of the cleaner production.Equipment: Laminar cells Tion V Lam-M1 (600x600x400mm), Tion V Lam -M2 (1200x600x400mm)Laminar ceilings Tion V Lam-2 (1800x1000x400mm); for low ceilings: Tion V Lam-2 H290 (1800x1000x290mm) Tion V Lam-2 (1800x1000x400mm); for low ceilings: Tion V Lam-2 H290 (1800x1000x290mm)
2 Disinfection and purification of supply air:Into the premises of the assistant, defect, blank and filling, seaming and control-marking, sterilization-autoclave and distillation rooms, fresh air is supplied through the ventilation system with disinfection and cleaning on filters of at least class H11 with inactivation of microorganisms at least 95% (requirements for class B according to SanPiN 2.1.3.2630-10). Since the rates of air exchange rate are low and amount to no more than 4 times, in cases of small rooms up to 50m2 it may be advisable to install compact supply ventilation (without laying air ducts) with air purification instead of central ventilation.Equipment: For central supply ventilation: duct disinfectants-cleaners floor-suspended: Tion Eco (capacity from 300 to 900 m3 / h) and Tion Eco (capacity 2000 and 3000 m3 / h); floor-standing: Tion Eco (capacity from 300 to 2400 m3 / h) and Tion Eco (capacity from 2000 to 25000 m3 / h).
3 Indoor air disinfection and purification:To reduce contamination and increase the frequency of air exchange, it is recommended to install autonomous disinfectants of air purifiers (recirculators) with a filtration class of at least F9 and inactivation of microorganisms on filters of at least 95% Equipment: Tion Clever disinfectant-air purifier in mobile and wall-mounted versions.
4Ensuring the frequency of air exchange and air purity standards:IIn the premises of pharmacies: control and analytical, washing, unpacking, as well as warehouses for storing stocks, the requirements for air purity are not regulated, but air exchange rates apply. They are achieved by arranging a central supply and exhaust ventilation system, or, if it is impossible or absent, by installing a compact supply ventilation with air purification in each separate room. Equipment: Tion Breezer 3S-air purifier in mobile and wall-mounted versions.
Tion allows for solution of all problems related to contaminated air removal both inside and outside the building.