The TION technology of active filtration works successfully all over Russia, solving extra-difficult medical and pharmaceutical air cleaning tasks.The specialists of the enterprise adapted the unique Tion technology and created special highly efficient equipment for all segment tasks, allowing for simultaneous air cleaning from viruses,smoke, soot, scents and harmful products of ambient air.
Organisation of air exchange in institutions In the premises of schools, educational institutions, reception, bedrooms, dressing rooms, nurseries, junior, middle, senior, preschool groups, as well as medical units and halls for music and gymnastics, the ventilation rate must be at least 2.5 times per hour. Since a child needs at least 20 m3/ for breathing, with an average number of children and staff in a group of 30 people, the minimum air exchange rate is 600 m3/ h, taking into account the requirements for a multiplicity of 2.5, at least 1000 m3 m3 h per room. Due to natural ventilation through slots in transoms and vents (inflow no more than 5-10 m3 h through 1 window) it is impossible to ensure even a minimum inflow rate. Hourly full ventilation of the room with open windows,especially in the cold season, is dangerous for the health of children. Thus, it is necessary to equip the room with a full central ventilation system, or install additional supply devices of sufficient capacity Equipment: fresh air disinfect-or (compact ventilation)Breezer Tion O2 or our flagship model Breezer TION 3S with air purification (up to 120-160 m3/ h, HEPA class air purification, climate control)
2 Cleaning and disinfecting indoor air If there is no central ventilation with air purification in rooms where there are strong sources of air pollutants (for example, if there are smokers for sick people in the room), it is advisable to install self-contained disinfecting air purifiers.Equipment: Tion Clever bactericidal air purifier (up to 150 m3/ h, H11 filtration, 99.9% disinfection, air purification from harmful substances to MPC standards).
3 With the right approach, simultaneously with an increase in infectious safety, it is possible to solve the problem of "stuffiness" and "air quality", which has a systemic nature, and as a result, improve the health and academic performance of students.Equipment: Tion Magic Air is a smart microclimate system. The compact gadget collects data on the air condition and gives commands to climatic devices (Breezer TION 3S, air conditioner, humidifier, etc.).Monitoring stations with T, H, CO2, PM2.5, PM10.
Organisation of air exchange in institutions In the premises of the preschool educational institution of reception, bedrooms, dressing rooms, nurseries, junior, middle, senior, preschool groups, as well as medical units and halls for music and gymnastics, the ventilation rate must be at least 2.5 times per hour. Since a child needs at least 20 m3/ for breathing, with an average number of children and staff in a group of 20 people, the minimum air exchange rate is 400 m3/ h, taking into account the requirements for a multiplicity of 2.5, at least 1000 m3 m3 h per room. Due to natural ventilation through slots in transoms and vents (inflow no more than 5-10 m3 h through 1 window) it is impossible to ensure even a minimum inflow rate. Hourly full ventilation of the room with open windows,especially in the cold season, is dangerous for the health of children. Thus, it is necessary to equip the room with a full central ventilation system, or install additional supply devices of sufficient capacity Equipment: fresh air disinfect-or (compact ventilation)Breezer Tion O2 or our flagship model Breezer TION 3S with air purification (up to 120-160 m3/ h, HEPA class air purification, climate control)
2 Indoor air disinfection and cleaning In the medical office of educational institutions (schools, colleges, etc.),disinfection should be provided. It is also recommended to install bactericidal air disinfection and purification plants. In addition, air disinfection is also advisable in rooms where children are constantly staying, especially during periods of growing number of diseases with airborne infections to reduce the incidence in pre-school groups. The placement of purifiers disinfectants allows the complex to improve sanitary and hygienic indicators in terms of air purity and air exchange rate.Equipment: Tion Clever (up to 150 m3/ h, H11 filtration, 99.9% disinfection, air purification from harmful substances to MPC standards,registration certificate for medical equipment)
3 Ventilation air purification In large and industrial cities, the concentrations of harmful substances in the places of placement of children's institutions often exceed the maximum permissible concentrations (MPC), while the concentration of harmful air substances in rooms with a constant stay of children (group, games,bedrooms, halls for music and physical education classes and others) should not exceed the maximum permissible concentrations (MPC) for the atmospheric air of populated areas. To solve this problem, at the design stage, integrated air purification installations should be laid in the ventilation supply duct. This will protect children and staff of the preschool educational institution from adverse environmental conditions and comply with sanitary standards.Equipment: channel cleaners Tion Eco air disinfect-ors (productivity from 400 to 27500 m3/ h)